WASH HEATER TROUBLE
MAIN PWB ASSEMBLY
1 2
When checking the voltage between connectors ( 1 , 2 ) during whites washing, Is the voltage 220 - 240V ~ ?
NO
Replace the MAIN PWB ASSEMBLY
220 - 240V~
YES
After power off,is the resistance of wire (RED-YELLOW) connectors between 10 ~30 ?
1 2 3
YELLOW
RED
YES
Normal
NO
After power off and the heater terminal is disconnected, is the resistance 10~30 ?
NO
Replace the HEATER ASSEMBLY
HEATING CONTINUOUSLY ABOVE THE SETTING WATER TEMPERATURE
MAIN PWB ASSEMBLY
2 4 (1)
When disconnect the connector (1) on the, MAIN PWB ASSEMBLY is the resistance of the natural connectors (White), (Blue/White) between 2.5k to 180k (105 ~0 )? 4 3
2 1
Replace the THERMISTOR
NO
(6322FR2046B)
YES
When checking THERMISTOR on the tub is the THERMISTOR loosened above 2mm from the rubber?
YES
Push the THERMISTOR tightly to the rubber.